What is the difference between UL1007, UL1061 and UL2468?

2025-09-02 Leave a message

1. 1061 is semi-rigid PVC, while 2468 is multi-core sheathed cable.


2. UL 2468 is for multi-core parallel cables, not multi-core sheathed cables, for cables with two or more cables in parallel. Available styles include single-sided dotted and cross-linked cables, double-sided dotted and cross-linked cables, and red-edged cables. These cables are unsheathed internal connecting cables, rated at 80°C, with PVC insulation and an average insulation thickness of approximately 0.45mm. UL 1007 is for general electronic wire used for internal connections in electrical appliances, rated at 80°C, with PVC insulation and an average insulation thickness of approximately 0.41mm. UL 1061 also falls under the category of single-core electronic wire, generally using semi-rigid SR PVC insulation with an average insulation thickness of approximately 0.25mm. Most cores are made of 1061 construction. UL styles such as 20276, 2725, and 2919 provide detailed specifications, including temperature resistance and operating environment. General performance requirements and test methods are provided in UL 758 and UL 1581.