EPR insulated marine power cables are suitable for transmitting power to various river and sea vessels, offshore oil platforms, and other water structures.
I. Production Implementation Standard
JB/T8140.1-1995
II. Operating Conditions
1. Rated voltage 0.6/1 kV
2. Permissible long-term operating temperature of the cable is 85°C
3. The minimum bending radius of the cable during installation should be no less than six times the cable's outer diameter.
III. Model and Name
CEF/DA EPR insulated, chloroprene-sheathed, marine power cable, Type DA, fixed installation
CEF80/DA EPR insulated, chloroprene-sheathed, bare copper wire braided armored marine power cable, Type DA
CEF82/DA EPR insulated, chloroprene-sheathed, copper wire braided armored, PVC sheathed marine power cable, Type DA
CEF90/DA EPR insulated, fluoroprene-sheathed, bare steel wire braided armored marine power cable, Type DA
CEF92/DA EPR insulated, fluoroprene-sheathed, steel wire braided armored, PVC sheathed marine power cable, Type DA
CEFR/DA EPR insulated, chloroprene-sheathed, flexible marine power cable, DA type. For connecting mobile electrical appliances.
CEV/DA EPR insulated, PVC sheathed, marine power cable, DA type. For fixed installation.
CEV80/DA EPR insulated, PVC sheathed, bare copper wire braid armored marine power cable, DA type.
CEV90/DA EPR insulated, PVC sheathed, bare steel wire braid armored marine power cable, DA type.
CEV82/DA EPR insulated, copper wire braid armored, PVC sheathed, marine power cable, DA type.
CEV92/DA EPR insulated, steel wire braid armored, PVC sheathed, marine power cable, DA type.