RVV stands for copper-core PVC-insulated, PVC-sheathed flexible cable, also known as lightweight PVC-sheathed flexible cable, which is what we commonly call soft-sheathed cable. RVV can be understood as consisting of two or more RV wires, then covered with a sheath. RVV cable is the most commonly used cable in low-voltage systems. It can have a variable number of cores, two or more, covered with a PVC sheath, and there are no specific requirements for the arrangement of the cores.

RVV is primarily used for power, control, and signal transmission lines in electrical appliances, instruments, electronic equipment, and automated devices. It can be used in burglar alarm systems and building intercom systems, among other applications.

RVV wire and cable are typically filled with cotton thread, PE rope, or PVC strips. The purpose of the filler: Because most conductors have a round cross-section, the filler material is necessary to provide a tight and solid support to prevent the wire from flattening when bent. The outer sheath's functions are: 1. Protects the cable's inner sheath from mechanical damage and chemical corrosion;

2. Enhances the cable's mechanical strength.

For example, an RVV model number might be: RVV2*1.5. What does each part represent?

RVV: R = Flexible Cord, V = Stranded Cord, RV = Stranded Cord (single wire, unsheathed), and V = Sheathed. RVV stands for Stranded Multi-Core Cord. 2*1.5 means two flexible cables, each 1.5 square meter in diameter. Cables with two or more cores are sheathed. 3*1.5 means three cores, and 4*1.5 means four cores.


Rated Voltage: 300V/500V.

Conductor: Stranded copper conductor, conforming to GB/T 3956 Class 5 (equivalent to IEC 60228.5).

Insulation: Polyvinyl Chloride (PVC) blend. Jacket: Flexible polyvinyl chloride (PVC) blend, gray (RAL7001).

Core Identification: ≤ 5 cores, colored cores; black cores with white numbers, yellow-green ground wire.

Core Count: 2-5, 7-36 (outside the CCC catalog, not CCC certified).

Cross-sectional Area: 0.75-2.5 mm², 0.5, 2.5-35 mm² (outside the CCC catalog, not CCC certified).

Test Voltage: 2000 V, 5 min.

Insulation Resistance: >200 MΩ × km.

Operating Temperature: -30°C to +70°C.

Bending Radius: 15 × cable outer diameter.

Flame Retardant: IEC 60332.1.

Reference Standards: GB 5023, IEC 60227, HD VDE 21.5 S3. Packaging sizes: 100m, 500m, and 1000m.

RVV Cable Applications

RVV cables are primarily used in flexible applications such as medium- and light-duty mobile appliances, instrumentation, household appliances, and power lighting. They can transmit both control and power signals and are suitable for installation in cable trays and flexible conduits. This product has obtained CCC and CE certification and complies with HD (European Harmonized Standards) requirements, making it suitable for both the Chinese and European markets. According to HD standards, this cable model is H05VV-F.