KVV22 3*2.5mm armored control cable
Copper core PVC insulated, PVC sheathed, steel tape armored control cable
KVV—Copper core PVC insulated, PVC sheathed control cable.
KVVPL—Copper core PVC insulated, PVC sheathed, aluminum foil shielded control cable.
KVV22—Copper core PVC insulated, PVC sheathed, steel tape armored control cable.
KVVRP—Copper core PVC insulated, PVC sheathed, braided shielded control cable.
KVVP2—Copper core PVC insulated, PVC sheathed, copper tape shielded control cable.
KVVP—Copper core PVC insulated, PVC braided shielded control cable.
KVVR—Copper core PVC insulated, PVC sheathed, flexible control cable.
Common control cable characteristics
Rated voltage: U0/U is 450/750V. The conductor core's long-term operating temperature is 70°C or 105°C, and the cable installation temperature must not be lower than 0°C.
The recommended allowable bend radius for cables is as follows:
For unarmored cables, the bend radius must be no less than 6 times the cable's outer diameter;
For armored or copper-tape shielded cables, the bend radius must be no less than 12 times the cable's outer diameter;
For shielded flexible cables, the bend radius must be no less than 6 times the cable's outer diameter.
Control cables generally refer to power supply/signal control cables for equipment and instruments.
Representative models include KVV/KYJV, and other instrument cables.
Control Cable Product Description
Implementation Standard: GB9330-88. Flame-retardant cables must also meet the technical requirements of IEC332-3. Model, Product Name, Voltage, Number of Cores, Cross-Section (mm²), Applications
KVV (KVV) cable, copper core, PVC insulated, PVC sheathed, 450/7504-370.75-10, for indoor installations in cable trenches, ducts, and other fixed locations.
KVV22 (KVV22) cable, copper core, PVC insulated, PVC sheathed, steel tape armored, 450/7504-370.75-10, for indoor installations in cable trenches, ducts, and other fixed locations that can withstand significant mechanical forces.
KVVP (KVVP) cable, flame-retardant copper core, PVC insulated, PVC sheathed, 450/7504-370.75-10, for indoor installations in cable trenches, ducts, and other fixed locations that can withstand significant mechanical forces. 70.75-10 is used for indoor installations in fixed locations such as cable trenches and ducts where shielding is required.
KVVR copper-core PVC insulated and sheathed flexible control cable 450/7504-370.75-10 is used for indoor installations where mobility is required.
KVVRP copper-core PVC insulated and sheathed braided shielded flexible control cable 450/7504-370.75-10 is used for indoor installations where mobility is required.
ZRKVV flame-retardant copper-core PVC insulated and sheathed ZRKVV cable 450/7504-370.75-10 For indoor installation in cable trenches, ducts, and other fixed locations requiring flame retardancy.
ZRKVV22 copper-core PVC-insulated, PVC-sheathed, braided steel-tape armored ZRKVV22 cable (450/7504-370.75-10) is for indoor installation in cable trenches, ducts, and other fixed locations requiring flame retardancy, such as direct burial locations that can withstand significant mechanical forces.
ZRKVVP copper-core PVC-insulated, PVC-sheathed, braided shielded ZRKVVP cable (450/7504-370.75-10) is for indoor installation in cable trenches, ducts, and other fixed locations requiring shielding and flame retardancy. Armored control cable KVV 32
ZRKVVR copper core PVC insulated PVC sheathed braided ZRKVVR cable (450/7504-370.75-10) is suitable for indoor installations where mobility and flame retardancy are required. Armored control cable KVV32
ZRKVVRP copper core PVC insulated PVC sheathed braided shielded ZRKVVRP cable (450/7504-370.75-10) is suitable for indoor installations where mobility, shielding, and flame retardancy are required.
High-temperature control cable (KGG cable) is suitable for signal detection in high-temperature environments with an AC rated voltage of 300/500 V and below. It is particularly suitable for control circuits in fire protection and security systems, as well as for power transmission lines.
The operating temperature range for high-temperature control cable is 200°C for long-term use and 1000°C for short-term use for 90 minutes.