• What is radiation ···
    2025-09-01 What is radiation shielded c···

    1. This can be understood as an ageing-resistant and weather-resistant cable.2. The sheath material and shielding layer must be relatively special.3. This means the outer sheath must be UV-resistant!4. The cable undergoes radiation treatment to alter its heat-treated structure, making the wire more

    read more >
  • Does the 1KV in VV···
    2025-09-01 Does the 1KV in VV-1KV 3*120···

    The 1KV in VV-1KV 3*120 means: 0.6/1kv.

    read more >
  • What does Cable MV···
    2025-09-01 What does Cable MVV stand fo···

    MVV is a PVC insulated and sheathed power cable for coal mines.

    read more >
  • What are the diffe···
    2025-09-01 What are the differences in ···

    1. The "P" at the front indicates separate shielding, while the "P" at the back indicates overall shielding.2. 2x1.0 cables are twisted first and then shielded. After shielding, they are cabled into 7 pairs of 2x1.0 cables. After cabling, the overall shielding is applied. This is

    read more >
  • What does each let···
    2025-09-01 What does each letter of the···

    The meaning of each letter of the CEHRG model: C: marine power cable. E: ethylene propylene rubber insulation H: chlorosulfonated polyethylene R: soft conductor G: This letter does not seem to be used on marine cables.

    read more >
  • What do the two Bs···
    2025-09-01 What do the two Bs in BVVB s···

    1. It stands for flat wire, meaning parallel wires.2. BVVB stands for copper-core PVC-insulated, PVC-sheathed flat cable for wiring.

    read more >
  • What does CX in CX···
    2025-09-01 What does CX in CXFR stand f···

    1. C: Marine. X: Natural styrene-butadiene insulation.2. CXFR ------- Natural styrene-butadiene insulation, chloroprene sheathed marine power flexible cable.

    read more >
  • What is total shie···
    2025-09-01 What is total shielding and ···

    1. The overall shield refers to the shielding of the entire cable, while the individual shields refer to the shielding of each wire pair. You can also think of it as the outermost shield being the overall shield, and the individual shields on each wire pair within it.2. Basically, the individual shi

    read more >
  • What is DN-F cable···
    2025-09-01 What is DN-F cable?

    1. Torsion-resistant, cold-resistant, and flame-retardant flexible cables for mobile wind turbines. The conductor is a flexible copper conductor. Conductors 6mm² and above adopt a stranded and twisted construction. The insulation is made of EPR, and the sheath is made of rubber based on chlorinated

    read more >
  • What is YJYD-6/6KV···
    2025-09-01 What is YJYD-6/6KV cable?

    YJYD-6/6KV is a 6 kV cross-linked polyethylene insulated polyethylene sheathed non-drip cable.

    read more >