1. product applications:
Flexible contortion-resistant cables for use in wind power systems or similar systems.
2.Use the feature :
2.1.Flame retardant performance: The single flame retardant test of the cable meets the requirements of GB/T18380.12-2008, and the beam burning test Class C meets the requirements of GB/T 18380.35-2008;
2.2.The cable meets 10000 times of torsional resistance test at normal temperature and 2000 times of torsional resistance test at low temperature;
2.3.The maximum load of the cable is 15N/mm2 The cable is resistant to moisture, salt spray, oil, ultraviolet and ozone.
3. Product usage characteristics:
3.1. Rated voltage: 450/750V, 0.6/1kV.
3.2. Max. Admissible operating temperature of conductor: 90℃, Max. 250℃ when conductor
short circuit (short circuit time not exceeding 5s).
3.3. Cable installation minimum bending radius: 6D(D- cable outer diameter,mm).
3.4. Cable installation environment temperature: ≥0℃; Ambient temperature: -40℃ to +65℃.
4. cable main technical indicators :
4.1 Conductor structure: annealed soft copper wire, in accordance with GB/T 3956 the class5 stranded conductor.
4.2 Insulation material: ethyl-propylene rubber mixture.
4.3 Jacket: Neoprene gum mixture or other equivalent synthetic elastomer.